Home
351 - 21st Street
Monroe, Wisconsin - 53566
Phone: 608.325.3141
 

H - Series
The H-Series Burners are designed to operate on gas, oil, or a combination of fuels at capacities ranging from 1,000,000 to 12,500,000 Btu/H. The H-Series Burners are designed for cast iron firebox or watertube boilers. The design of these units feature low CO performance, a unique air damper for easy combustion set-up independent low and high fire adjustment .

Features Include:

  • Pressure atomizing burner
  • Gas manifold on oil burners for upgrade to combination units
  • Backward-curved impeller with lifetime warranty
  • Multi-blade-type air damper systems with silencer
H - Series

Capacities and Specifications

Burner Size 10131517 202125
Oil Input (U.S. gph) 7.29.310.712.1 14.21517.8
Gas Input (Btu/hr) 1,0001,3001,5001,700 2,0002,1002,500
Boiler Horsepower 24313641 485060
Blower Motor Horsepower 1/21/21/21/2 1/23/43/4
Shipping Weight (lbs) 450450450450 450450450
Burner Size 30343540 4245
Oil Input (U.S. gph) 21.424.32528.6 3032.1
Gas Input (Btu/hr) 3,0003,4003,5004,000 4,2004,500
Boiler Horsepower 72818496 100108
Blower Motor Horsepower 3/4111-1/2 22
Shipping Weight (lbs) 500500500600 600600
Burner Size 50545560 6370808490
Oil Input (U.S. gph) 35.738.639.342.9 455057.16064.3
Gas Input (Btu/hr) 5,0005,4005,5006,000 6,3007,0008,000 8,4009,000
Boiler Horsepower 119129131143 150167191200215
Blower Motor Horsepower 2333 55557-1/2
Shipping Weight (lbs) 700700700700 700700700700700
Burner Size 100105110120 125
Oil Input (U.S. gph) 71.47578.685.7 90
Gas Input (Btu/hr) 10,00010,50011,00012,000 12,600
Boiler Horsepower 239250262286 297.6
Blower Motor Horsepower 7-1/27-1/27-1/210 10
Shipping Weight (lbs) 1,1001,1001,1001,450 1,450

Gas Based:

Model Fuel
HGGas

Oil Based:

Model Fuel
HLNo. 2 Oil

Gas/Oil Based:

Model Fuel
HLGGas/No. 2 Oil

Notes:

  • Firing rates based on 60 cycle and altitudes to 2000ft. above sea level. For impeller and motor sizes at higher altitudes, and 50 cycle applications, consult factory. Gas input based on 1000 Btu/cu. ft. and .60 specific gravity oil input based on 140,000 Btu/gal.
  • Oil input based on No. 2 oil @ 140,000 Btu/gal
  • Gas input based on Natural Gas @ 1,000 Btu/cu.ft and 0.60 specific gravity
  • Capacity based on neutral tp 0.75" wc furnace pressure for model H10-25, neutral tp 1"wc for model H30-45, neutral to 2"wc for model H50-90, and furnace pressure upto 3"wc for model H100-120